How to protect outdoor LED display from lightning?

Apr 22, 2024

Leave a message

How to protect outdoor LED display from lightning?

 

LED display lightning protection knowledgeThere are four main parts of lightning protection for outdoor LED displays

 

1. Direct lightning protection of the outdoor screen, if the outdoor screen is not within the direct lightning protection range of the nearby tall buildings, a lightning rod shall be set on the top of the steel structure of the screen or nearby.

 

2.The outdoor screen of the induction lightning protection

 

a. The large-screen power supply system does level 1-2 power lightning protection, and the signal line is equipped with signal lightning protection.

 

b. The power supply system of the computer room is protected by level 3 lightning protection, and the signal surge protector is installed at the equipment end of the signal out/out of the computer room.

 

3. All LED large screen lines (power and signal) should be shielded and buried.

 

4. The front-end (outdoor screen) and the grounding system of the computer room should meet the system requirements. (Generally, the front-end grounding resistance should be less than or equal to 4 ohms, and the grounding resistance of the computer room should be less than or equal to 1 ohm) LED display lightning protection LED display has a wide range of applications, not only indoors, but also many outdoor applications. Depending on the use of the LED display, the installation position is also different, and some are also installed outdoors at a high place, while the mounting bracket is generally iron.

In the summer thunderstorm season, the probability of LED display becoming the target of lightning strikes is very high. Once the LED display is struck by lightning, because it is a high-density integrated display, it is highly sensitive to anti-interference, and the harm of lightning to it will cause mechanical, electrical, thermal damage, and even cause fire.

 

Therefore, lightning protection measures for LEDs are indispensable.

 

Lightning measures for LED display:

 

1. For the protection of direct lightning, install a lightning rod on the supporting structure of the LED display (outdoor), and the indoor LED display or the LED display of a tall building next to it can not consider the installation of lightning rods.  

 

2. In view of the counterattack of the steel structure, connect the rigid structure with the shell of the ED display screen, do a good job of equipotential, and do a good job of grounding, the grounding resistance value is generally required to be less than 10 ohms, if the resistance value does not meet the requirements, it is necessary to do additional artificial grounding grid. The lightning protector should also be grounded.   

 

3. For the lightning current induced on the power line, install a single-phase or three-phase power surge protector on the power line. The cross-sectional area of the connecting wire of the phase wire shall not be less than 10mm square, and the cross-sectional area of the connecting ground wire shall not be less than 16mm square.   

 

4. For the lightning current induced on the signal line, install a signal lightning protector on the signal line. The signal arrester is determined according to the signal interface of the system, if it is a network cable, the network signal lightning protector is installed, and the serial interface is installed DB9 interface lightning arrester and so on. The cross-sectional area of the connecting ground wire shall not be less than 1.5mm square.   

 

 

How to better protect against lightning?

 

1. Direct lightning protection: In an open area, there are no tall buildings around, which proves that your pole is located in the LPZOA area and is prone to direct lightning. Therefore, it is necessary to add a lightning rod, and the height of the lightning rod is calculated by the rolling ball method. If it is too troublesome, the previous 45-degree polyline method (centered on the tip of the lightning rod, and the place where the 45-degree angle cover is under the scope of protection) can also be used, but the accuracy is not so high.

 

2. Lightning protection and grounding network: If the lightning rod is installed, it is necessary to make a simple ground network as a discharge channel for lightning. Usually, it is more cost-effective to use angle steel to connect with flat steel. 

 

3. Surge protection measures: Because there are optical transceivers and video servers in the distribution box, their power supply must be guaranteed, so a lightning protection socket is designed at their power supply to protect the power supply.

 

The signal lines that are introduced into the power box should be installed with lightning protection devices that match the voltage and interface. There is no need to install the optical fiber end, because the optical fiber is an insulating equipment and will not be affected by induced lightning, but the optical fiber reinforcing core must be grounded nearby to avoid damage to the optical fiber by electrostatic induction and lightning thermal effect.

Send Inquiry